Domestic thermal analysis instrument professional manufacturer
Dedicated to thermal analysis instrument for more than 20 years
Instrument introduction
Differential scanning calorimetry (DSC), as a classical thermal analysis method of thermal effect under controlled program temperature, has been widely used in the research and development, process optimization, quality control and failure analysis of various materials and chemistry fields. Using DSC, we can study the phase transformation of inorganic materials, melting of polymer materials, crystallization process, polycrystalline phenomenon of drugs, solid/liquid phase ratio of food such as fats and fats.
Instrument use
Physical and chemical changes related to heat are measured, such as glass transition temperature, melting point, melting temperature, crystallization and crystallization heat, phase transition reaction heat, thermal stability of the product, curing/crosslinking, oxidation induction period, etc.
Instrument characteristics
The thermal flow differential scanning calorimeter has good repeatability and high accuracy, which is especially suitable for precise measurement of specific heat.
Self-developed constant temperature controller, constant temperature gas chromatography, mass spectrometry connection head, constant temperature belt, can fully ensure the tar and various reaction gas secondary detection.
The whole machine is integrated, the temperature control and the furnace body device are integrated, and the signal loss and interference are reduced.
Perfect two-way atmosphere control system, using mass flow controller; During the measurement process, two air intake modes can be selected, and the software sets automatic switching.
The instrument is equipped with standard material, and the user can adjust the temperature range by himself to reduce the error of the instrument.
Intelligent software design, automatic drawing of the instrument, software can realize a variety of data processing, such as enthalpy calculation, glass transition temperature, oxidation induction period, substance melting point and crystallization and so on.
The instrument can automatically generate DSC and oxidation induction period experimental report.
Large screen LCD display, real-time display of instrument status and data, two sets of temperature measurement couples, one set of couples to display the sample temperature at work, the other set of couples to display real-time furnace temperature (whether the heating furnace is working or not).
The machine is equipped with RS232 and USB interface and intelligent software, which can realize automatic program control and setting.
The instrument has the function of remote operation, maintenance and adjustment (the instrument can be remotely operated through the Internet).
Instrument index
Temperature data | DSC data | ||
Temperature range | HSC-1: Room temperature ~ 680℃ | Measuring range | ±500mw |
HSC-2: -30 ~ 680℃ (Mechanical refrigeration) | |||
HSC-3: -60 ~ 680℃ (optional refrigeration system of different specifications) | Minimum resolution | ±0.1μw | |
HSC-4: -150 ~ 680℃ (liquid nitrogen refrigeration) | |||
Temperature accuracy | ±0.1℃ | Power noise | ±0.1μw |
Heating rate | 0.1℃/min~100℃/min | ||
Temperature repeatability | ±0.1℃ | Power accuracy | ±0.1μw |
Temperature control mode | Heating, constant temperature (program automatic system) | (Optional) Constant temperature controller Constant temperature gas chromatography, mass spectrometry connection head constant temperature belt | Constant temperature range: room temperature ~ 200℃ |
Cooling method | Air cooling | ||
Characteristic function | |||
Display mode | Chinese characters large screen LCD display | Atmosphere system | Gas mass flow controller; Automatic switching between two gas channels can be set |
Crucible volume | 0.06ml | Gas velocity | 10~200mL/min |
Crucible arrangement | Aluminum oxide, high purity aluminum (standard) | Optional crucible | Sealing liquid aluminum crucible (sample packer) Sealing solid aluminum crucible (sample packer) Zirconia, quartz, graphite, platinum rhodium (users can choose according to their own needs) |
Software advantage | Intelligent, selectable baseline correction with reference materials (indium, tin, lead, zinc, aluminum) allows the user to adjust the temperature and enthalpy |